Post Support Typ P
![]() |
![]() |
![]() |
COLUMN BASE TYPE P ON CONCRETE
*Structural calculation example (The load bearing capacities are only indicative. Detailed static information can be found in the upper section in documents / download)
Art. No. | Post [mm] | Pressure F1,Rk | Tension F1,Rk | F2/3,Rk | F3/4,Rk | |
---|---|---|---|---|---|---|
min w | min h | Steel [kN] | ||||
19832060 | 120 | 120 | 93,4 | 10,6 | 7,71 | 7,71 |
19832100 | 120 | 120 | 93,4 | 10,6 | 4,53 | 4,53 |
19832150 | 120 | 120 | 93,4 | 10,6 | 2,99 | 2,99 |
4 screws Ø 10 x 120 mm
Order no.: 19832060
EAN: 4019346510209
Variant selection(All Orange marked in combination possible):
Are you a customer or a new customer? (Specialist trade) | ||
For more information about our products, orders, invoices and promotions, log in to our new shop system (account above). |
Technical Features
Material: | S 235 JR |
Bodenplatte Stärke: | 6 |
Trägerplatte Stärke: | 6 |
Trägerplatte Breite: | 100 |
Rohr Ø: | 48,3 |
Bodenplatte Breite: | 130 |
Rohr Höhe: | 60 |
D Ø Höhe: | Ø 48,3x60 |
Carrier plate mm L x B: | 100x100 |
Ø 11 mm: | 4 |
Base plate mm L x B x T: | 130 x 130 x 6 |
Ø 13 mm: | 4 |
ETA-16/0550: | ETA-16/0550 |